-
Atlas Copco Tools Talk Software Download
Control Assistant software provides powerful troubleshooting and maintenance tools for Woodward's MicroNet family, Atlas family, and NetCon product lines. Control Assistant software provides powerful troubleshooting and maintenance tools for Woodward's. Free Download: Tools Talk Atlas Copco. My SCUBA Diary for Linux 2. Published: 2. 8 January, 2. My SCUBA Diary is a free, lightweight logbook to manage. Atlas Copco Tools is the leading supplier of industrial power tools and assembly systems to the manufacturing industry. Download the apps on the link below.
. User Guide Focus 60 / Focus 61 Atlas Copco Industrial Technique AB 9839 02-01 Edition 1.1. Overview updated (chapter 2), Focus 60 / Focus 61 Ethernet Ports updated (par. 4.4), Focus 60 / Focus 61 Barcode Scanner Interface (RS232) updated (par. 4.5), Focus 60 / Focus 61 I/O BUS (CAN) updated (par. 4.6), Focus 60 / Focus 61 10.1.0 5.5.1.x.
Focus 60 / Focus 61 LEDs.22 Focus 60 / Focus 61 Ethernet Ports. 23 Focus 60 / Focus 61 Barcode scanner Interface (RS232).
24 Focus 60 / Focus 61 I / O BUS (CAN).26 Focus 60 / Focus 61 Wave Flexible Antenna.28 WORKING WITH ToolsTalk BLM. Focus 60 / Focus 61 SETTINGS.89 10.1 Device Data.89 10.2 Device Settings. 89 10.2.1 Focus 60 / Focus 61 Basic settings. 90 10.2.2 Result Filters Settings.91 10.2.3 Barcode Scanner Settings.91 10.2.4. Safety Information Focus 60 / Focus 61 User Guide SAFETY INFORMATION WARNING: PLEASE READ CAREFULLY THE FOCUS 60 / FOCUS 61 SAFETY INFORMATION (No. 9834 4137 00) PRIOR TO USE THE PRODUCT AND PAY ATTENTION TO THE SAFETY INSTRUCTIONS PROVIDED. Focus 60 / Focus 61 User Guide Introduction INTRODUCTION About this Document This document is a User Guide for the Focus 60 / Focus 61: it consists of the following main parts: Part Name Description This chapter introduces this User Guide and provides.
Reference Documents Hereunder a list of important documents, useful for a complete view of the product in all its applications: Focus 60 / Focus 61 Safety Information (No. 9834 4137 00): Multilanguage Safety Information and Declaration of Conformity . Focus 60 / Focus 61 User Guide Introduction DIMENSIONS The unit of the dimensions is in mm. INTERFACES Ethernet ports Barcode Scanner interface (RS232) I / O BUS (CAN) Wave Flexible Antenna connector Radio module frequencies: Country Number Channel Frequency MHz Data rate bit/s 868.034. Introduction Focus 60 / Focus 61 User Guide Country Number Channel Frequency MHz Data rate bit/s 869.573 38400 869.840 38400 868.034 19200 868.297 19200 868.502 19200 868.706 19200 869.006 19200 869.273 19200 869.573 19200 869.840 19200 902.791 38400 906.478 38400 907.004. 40 °C (104 °F) Altitude: Up to 2000m SYSTEM REQUIREMENTS Hereunder are the PC minimum requirements for installation of Focus 60 / Focus 61 Management Software (ToolsTalk BLM): Processor: 400 MHz (800 MHz or above recommended) . Focus 60 / Focus 61 User Guide EC Declaration of Conformity The Focus 60 / Focus 61 is in conformity with the requirements of the council Directives on on the approximation of the laws of the Member States relating: .
Download Macromedia Freehand free setup for windows. Macromedia Freehand Overview Freehand is one of the best creative vector graphics design tools for making creative design and multipage page production. The simple and well managed interface of it clearly shows that it was designed by a high dollar programmer. Macromedia freehand 10 full version free download. It is fully loaded with latest graphic editing tools and features. It is a smart graphic designing tool that could be use for making creative design, storyboarding, multipage document production, and editing.
Safety requirements for electrical equipment for measurement, control, and laboratory use. General IEC EN 61010-1:2010 requirements. NOTE: The internal battery of the Focus 60 / Focus 61 is in conformity with the following harmonized standard: Primary batteries – Part 1: General. IEC 60086-1:2015. Focus 60 / Focus 61 User Guide SYSTEM OVERVIEW The Focus 60 / Focus 61 is a controller designed to manage a production line station where mechatronic MWR wrenches are used to do tightening operations.
The Focus 61 can manage up to 10 MWR-TA divided into two stations. On each station, one MWR-TA can be active at a time.
Focus 60 / Focus 61 User Guide System Overview The Focus 60 can manage only one MWR-TA on one station: Focus 60 ToolsTalk BLM Station 1 MWR-TA Hereunder are the main functions of Focus 60 / Focus 61: MAIN FUNCTIONS. Antenna (Antenna (868 MHz) → P/N 4027 5022 13) (Antenna (915 MHz) → P/N 4027 5022 14) The Antenna is installed on the Focus 60 / Focus 61, for communicating with the MWR-TA. 16 (106) 9839 0211 01 Edition 1.1. Focus 60 / Focus 61 User Guide System Overview The following additional module for Focus 60 / Focus 61 is available: Stacklight (P/N 8433 0570 13) Colored lamps for a real time indication of the tightening results, system status etc. Installing Focus 60 / Focus 61 WARNING: Install the Focus 60 / Focus 61 close to the AC Power in order to manage it easy. NOTE: Position the Focus 60 / Focus 61 so that the On-Off switch is easily accessible.
NOTE: By using the On-Off switch (placed on the bottom side of the Focus 60 / Focus 61), switch the Focus 60 / Focus 61 on, to verify that the installation is correct. Check that the light of the On-Off switch is red and that the other LEDs (placed on the front panel) illuminate correctly. If a MWR-TA is associated with one Station of the Focus 60 / Focus 61, but either the batteries level of the MWR-TA is too low or the MWR-TA is out of the range of the Focus 60 / Focus 61, the following. Focus 60 / Focus 61 User Guide User Interfaces Associate the MWR-TA with a Station of the Focus 60 / Focus 61.
After few seconds, the Focus 60 / Focus 61 shows the data of the ongoing tightening operation on the MWR-TA (refer to the following. It slides up the fields of the settings and increases value in settings menu. Focus 60 / Focus 61 LEDs There are three LEDs on the Focus 60 / Focus 61front panel: LED color Description The Blue LED is on when the system is ready. User Interfaces Focus 60 / Focus 61 Ethernet Ports The Ethernet Port allows the communication between the Focus 60 / Focus 61 and ToolsTalk BLM. Two Ethernet Ports characterize the Focus 61 (Focus 60 has only one).
See the pictures below. Focus 60 / Focus 61 User Guide Focus 60 / Focus 61 Barcode scanner Interface (RS232) The Focus 60 / Focus 61 has a barcode interface RS232 (see the pictures below) with a switchable 5V power supply (max 400 mA).
Focus 60 / Focus 61 User Guide User Interfaces No Prefix No Suffix TERMINATOR: CR + LF Terminator Specification: Focus 60 Focus 61 Barcode interface RS232 Barcode interface RS232 9839 0211 01 Edition 1.1 25 (106). Focus 60 / Focus 61 I / O BUS (CAN) I / O BUS (CAN) (see the pictures below) connects the Stacklight to the Focus 60 / Focus 61. The Stacklight is an optional tool that supplies a real time indication of each tightening result, system status, etc. Focus 60 / Focus 61 User Guide User Interfaces Focus 60 Focus 61 I/O BUS (CAN) I/O BUS (CAN) 9839 0211 01 Edition 1.1 27 (106). Focus 60 / Focus 61 User Guide Focus 60 / Focus 61 Wave Flexible Antenna The Wave Flexible Antenna (see the pictures below) allows the Focus 60 / Focus 61 to communicate with the MWR-TA. The Wave Flexible Antenna parameters are as follows: . It offers user-friendly programming and real time monitoring.
ToolsTalk BLM is a configuration interface between the user and the Focus 60 / Focus The main features that characterize the configuration interface between the user and the Focus 60 / Focus 61 are as follows: . Working with ToolsTalk BLM Focus 60 / Focus 61 User Guide Software Installation NOTICE Install ToolsTalkBLM with PC administrator rights. NOTICE Do not install the software from a shared folder/drive. Install the software from the supplied CD; if the CD content is copied into a PC folder, it must be a PC local folder. Focus 60 / Focus 61 User Guide Working with ToolsTalk BLM Click Yes in order to uninstall the ToolsTalk BLM software version installed on the computer.
After clicking Yes, it is possible to continue with the installation process: Click Next to continue the installation process. Working with ToolsTalk BLM Focus 60 / Focus 61 User Guide The following Installation screen alerts the operator that ToolsTalk BLM is being installed: Before to finish the installation process, the screen on the right shows: After clicking Ok, the following Installation screen is. ToolsTalk BLM” option is flagged Click Finish; ToolsTalk BLM is automatically started.
After installing the software, run the program by selecting Start → All Programs → Atlas Copco Tools AB → Tools Talk BLM: 9839 0211 01 Edition 1.1 33 (106). 60 days. Once the software is installed, enter the registration form by selecting Start → All Programs → Atlas Copco Tools AB → ACTLicense (refer to the screen on the right). Software upgrade If there is a software update of ToolsTalk BLM, simply install the new version. Connecting with the Focus 60 / Focus 61 NOTE: This paragraph describes the connection between Focus 61 and ToolsTalk BLM. The procedure to connect Focus 60 with ToolsTalk BLM is basically the same.
Click ToolsTalk BLM icon to launch the software. Working with ToolsTalk BLM Focus 60 / Focus 61 User Guide If necessary, select “Focus 60” or “Focus 61” in the Target Device area as shown in the screen below: Select “Focus 61” in the Target Device area Turn the Focus 61 on and wait until the initialization is completed. Geekbench 2 v2 4 0 ipad. Focus 60 / Focus 61 User Guide Working with ToolsTalk BLM After turning the Focus 61 on, click Connect icon: Search Devices option, IP Connection option and the list of devices connected with the network show (see the screen below). Working with ToolsTalk BLM Focus 60 / Focus 61 User Guide Select the desired device. Then wait until ToolsTalk BLM interface shows: Menu list Target Device area Toolbar Device Data and Device Settings Device Files area Linked Wrenches Busy Wrenches.
Super User (available only for Atlas Copco Service Personnel) 5.4.1.1 Enabling LOG Viewer Enable LOG Viewer to trace the ToolsTalk BLM operations with the Focus 60 / Focus 61: this is helpful for troubleshooting activities. Select Tools → Log Viewer: 9839 0211 01 Edition 1.1. Focus 60 / Focus 61 User Guide The window on the right shows: Click Show Log to display the information related to the “Log Messages” (operations made between the ToolsTalk BLM and the Focus 60 / Focus 61): 40 (106) 9839 0211 01 Edition 1.1.
5.4.1.2 Download LOG Select Tools → Download LOG to download the LOG file stored in the Focus 60 / Focus 61 memory. After clicking, the following pop-up shows: Folder icon Click the Folder icon to select the destination folder of the LOG file. Working with ToolsTalk BLM Focus 60 / Focus 61 User Guide Click the “Folder” icon (see the above pop-up) to define the Backup File; the following window shows: Text box of the Focus Backup File name Type the Focus Backup File name into the related text box (see the figure above) and select the desired “destination folder”. Focus 60 / Focus 61 User Guide Working with ToolsTalk BLM 5.4.1.3.2 Performing Restore / Update NOTE: Please, clean the system before restore backups. For both Stations, click Memory (placed in the Device Files area); the pop-up on the right shows: Click “Delete objects”. Focus Backup File (.fbk).
For the Firmware Upgrade File (sent by manufacturer to upgrade the Focus 60 / Focus 61) open the drop down list on the right of the “File name” text box and select Firmware Upgrade File (.ud). Focus 60 / Focus 61 User Guide Working with ToolsTalk BLM “Focus starts Update process” automatically (see the figure on the right). At the end of the “Focus Update process” a “Settings saved” pop-up shows (see the figure on the right).
DESCRIPTION “Connect” icon connects the ToolsTalk BLM with the Focus 60 / Connect Focus 61. “Reload” icon reloads the data of the Focus 60 / Focus 61 Reload connected. “Live Monitor” icon opens the Live Monitor functions, showing in real time the tightening from the connected wrenches. 5.4.3 Status bar The status bar shows the connection status between Focus 60 / Focus 61 and ToolsTalk BLM. When the connection between Focus 60 / Focus 61 and ToolsTalk BLM is stable, a green bullet followed by “Connected” represents.
The Focus 61 can manage one or two stations, while the Focus 60 can manage only one station. The stations are virtual, used by the software to let the device manage the jobs of the operators working, for instance, of the two sides of the same assembly area (in the case of the Focus 61).
Programming Focus 60 / Focus 61 The Jobs start either automatically when the Focus 60 / Focus 61 turns on or starting the operation by external signal given by scanning a barcode string or by the AOP command (refer to paragraph “Events Configuration”). Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide Stations Configuration Device Files area Focus 60 / Focus 61 connected Click the minus or plus symbols to close or open menus 50 (106) 9839 0211 01 Edition 1.1. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 The Device Files area defines the stations associated with the Focus 60 / Focus 61 connected. For each station there are MWR-TA associated, which execute the Jobs programmed.
Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide Associating the MWR wrenches with Station(s) Station1 MWR-TA associated with Station1 Station2 MWR-TA associated with Station2 It is possible to associated up to 10 MWR-TA with a Focus 61, divided into the two Stations (one MWR- TA on one Station for Focus 60). Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 The Linked Wrenches section lists all the usable MWR-TA. The MWR-TA shown as available or busy are only the MWR-TA powered on and visible from the controller via radio. MWR-TA model Wrench Type Serial number marked on the MWR wrench Serial Number Base SN Serial number of the Focus 60 / Focus 61 Firmware version loaded on the MWR-TA Minimum Torque Minimum torque values for the MWR-TA model Maximum Torque. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 To associate a MWR-TA with a Station, drag one of the available MWR-TA and drop it into the Wrench menu of the Station (refer to the figure below).
Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide To remove a MWR-TA from the Station either drag and drop it into the trash bin or right-click and select Remove Wrench (see the figure on the right). Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 To make a “Busy Wrench” available: Connect the controller that is associated with the wrench. Remove the wrench. In case that the controller is off or disconnected, it is possible to unlink the wrench by right.
Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide Pset Configuration The set of parameters that controls a tightening process is contained into a so-called Pset. This section describes how to configure the Pset parameters necessary to do a tightening. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 The Pset Toolbar (placed in the upper area of the above Pset window) provides the following functions: ICON FUNCTION DESCRIPTION Save the Pset parameters Save Start the Pset on the MWR-TA. Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide The Pset consists of the following parameters: SETTINGS FUNCTION DESCRIPTION Hereunder is a list of available strategies: Strategy Torque controlled: Only the torque is measured. The test result is OK if the maximum torque applied during the tightening is. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 TORQUE LIMITS FUNCTION DESCRIPTION Cycle Start Torque value from which the measurement of the tightening starts Minimum torque and Torque limits to get a positive result Maximum torque Torque limit for which the screw could be damaged by the excessive torque applied. Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide FUNCTION DESCRIPTION Rehit Value (°) If the torque reaches the click value within this angle, it means that the screw was already tightened.
In this case the result is marked as RNOK or ROK. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 Job Configuration The Job is a set of tightening operations (steps) performed by the MWR-TA associated with a station. Each MWR-TA must be configured with its Pset as described in the paragraph above. Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide PARAMETER DESCRIPTION Job Order Fixed: The Steps of the Job are executed in the order specified in the window above.
Free: The Steps of the Job are executed according to the Optional Trigger defined in the Step parameter. NOTE: It is not possible to modify a step already saved.
To remove a step, select it and click Remove icon ( ). NOTE: It is MANDATORY to disconnect the ToolsTalk BLM to use Focus 60/ Focus 61 and start a Job. Focus 60 / Focus 61 User Guide The following parameters configure the Identifier: START JOBS Initialize Select the Job to use when the Focus 60 / Focus 61 is initialized. Station Message area selects the signal that start a Job / Job step. Message Select the signal between the following options: . Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 ABORT JOBS Message area selects the signal that stop a Job.
Message Select the signal between the following options: Barcode AOPsetvin AOPIdentifier Define the following parameters: . It defines the position of the characters that arranges the substring of the command to use as result. I/O Accessories I/O Accessories option configures the accessories utilized during the Focus 60 / Focus 61 operations. Right-click the I/O Accessories icon placed in the Device Files area in order to open the New Accessory. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 After selecting Add Accessory, the following window shows: 9839 0211 01 Edition 1.1 69 (106). Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide DEVICE Type Accessory used Available This drop-down list selects the ID channel to use in order to configure the Stacklights accessory CONFIGURATION “Lamp” section configures the behavior of each lamp.
The Stacklight mounts up to 5 Lamp configurable lamps. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 CONFIGURATION 3. Click Setup: The Setup screen right shows: 4. Select the event condition to associate with the lamp.
After selecting the event condition, the editable section on the right of the Setup screen gets automatically. Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide CONFIGURATION The “Behaviuor column” summarizes the editable section. Configure the editable section by setting temporary intervals of flashes and signal duration. Finally click Set (placed on the lower right corner of the editable section). Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 CONFIGURATION The external device sends one of the following signals to the Stacklight: Digital Inputs Buzzer Do the following procedure to configure “Buzzer” section.
Check the box in correspondence of “Mounted”; the Setup button gets automatically. Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide CONFIGURATION 3. Select the event condition. After selecting the event condition, the editable section on the right of the Setup screen gets automatically active (refer to the following. Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61 CONFIGURATION Digital Do the following procedure to configure “Digital Outputs” section. Check the box in correspondence of “Mounted”; the Setup button gets automatically active (refer to the following screen): After checking the box in correspondence of “Mounted”, Setup button gets automatically active.
Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide CONFIGURATION 3. Select the event condition. After selecting the event condition, the editable section on the right of the Setup screen gets automatically active (refer to the following screen). NOTE: No effects resulting from special conditions should be detected when the Focus 60 / Focus 61 is integrated into systems.
After a lengthy advertising campaign which included the creation of a website from its main character’s point of view and a viral marketing website on which filmgoers could register for a lottery number to save them from the ensuing disaster, 2012 was released internationally on November 13, 2009. The film refers to Mayanism and the 2012 phenomenon in its portrayal of cataclysmic events. The way of the world movie in youtube. Critics gave the film mixed reviews, praising its special effects and dark tone relative to Emmerich’s other work and criticizing its screenplay and length.
Once the Focus 61 is configured as described in the previous paragraph “Programming Focus 60 / Focus 61”, it is possible to start a Job on the Station(s). Status Torque peak Angle Torque click Refer to the following results status list for possible results status that can be shown on the Focus 60 / Focus 61 display: = Torque and angle within the limits (OK) . Focus 60 / Focus 61 User Guide Executing Tightening Operations The following “Torque – Angle” graph shows all relevant Parameters Settings values. According to them, the following example points the fields out that detect the results status above mentioned: 9839 0211 01 Edition 1.1. Executing Tightening Operations Focus 60 / Focus 61 User Guide More precisely: 80 (106) 9839 0211 01 Edition 1.1. Focus 60 / Focus 61 User Guide Live Monitor LIVE MONITOR The Live Monitor icon shows in real time the tightening results of the MWR-TA connected with ToolsTalk BLM.
After clicking Live Monitor, after executing a tightening with a linked MWR-TA, the following screen. Live Monitor Focus 60 / Focus 61 User Guide Hereunder are the fields displayed in the above Result Monitor screen: FUNCTION DESCRIPTION Serial number of the MWR-TA Wrench serial number Result ID IDN defined in the Job IDN1: IDN2: IDN3: NOTE: If the ToolsTalk BLM is connected, the IDN is NOT visible.
Focus 60 / Focus 61 User Guide Live Monitor NOTE: For Psets executed directly on the MWR-TA, it is possible to open a Live Monitor interface for each MWR-TA: 2. Start the Pset 3. Live results monitor for the selected MWR-TA 1. Results Viewer Focus 60 / Focus 61 User Guide RESULTS VIEWER The Results Viewer icon shows a list of the tightening results of all MWR-TA connected with ToolsTalk BLM. After clicking Results Viewer, the following Filters selection pop-up shows: Optional filters area. Focus 60 / Focus 61 User Guide Results Viewer Wrench Status filter: click the drop-down list and select between the results status list (see the list on the right): After setting Wrench Status filter, click Add.
Wrench Serial filter: set the Wrench Serial filter with one of the following procedures. Results Viewer Focus 60 / Focus 61 User Guide The summary area is automatically filled (see the following screen). “Remove” button (placed on the right of the Summary area) removes the filters inserted in the Summary area singularly. “Clear” button (placed below “Remove” button) removes all of the filters inserted in the Summary area at the same time. Focus 60 / Focus 61 User Guide Results Viewer After recording the Filters selection pop-up, click OK; the following screen shows: Load results icon 9839 0211 01 Edition 1.1 87 (106). Results Viewer Focus 60 / Focus 61 User Guide Click Load Results icon to load the results set previously; the following results list shows: Results Viewer toolbar The Results Viewer toolbar shows the following commands: Load Results icon It loads all the results set in the Filters selection pop-up.
LAN version of the Focus 60 / Focus 61 Focus 60 / Focus 61serial number Serial Number NOTE: When programming the Focus 60 / Focus 61 from ToolsTalk BLM, ensure that the Focus 60 / Focus 61 is in the main menu. Language: it selects the Focus 60 / Focus 61 language from the related list (refer to the screen below). Click “Set Language” to confirm: Measuring unit: it selects the Focus 60 / Focus 61 measurement unit from the related list (refer to the screen below). Click “Set Measuring Unit” to confirm: . Focus 60 / Focus 61 Settings Date and time: It selects the Focus 60 / Focus 61 Date and Time from the related section (refer to the screen below).
Click “Set Date & Time” to confirm: NOTE: Click the icon to match the time set on the PC with the time of the Focus 60 / Focus 61. Focus 60 / Focus 61 User Guide 10.2.4 Display Settings Set both the Brightness and Contrast on the Focus 60 / Focus 61 from the related section placed in the Display Settings (refer to the screen below) and click respectively “Brightness”. Focus 60 / Focus 61 User Guide Working with Open Protocol WORKING WITH Open Protocol NOTE: Compatible Atlas Open Protocol (AOP): 1.6.3 Atlas Open Protocol (AOP) is a communication protocol that interfaces directly with the Focus 61. To enable this application, double-click the Open Protocol icon placed in the Device Files area (refer to the picture above: Connections section). Working with Open Protocol Focus 60 / Focus 61 User Guide After enabling the Open Protocol (by clicking Enabled box placed in Open Protocol section – refer to the screen above), it is possible to access the Advanced Settings (by clicking Advanced Settings button). Focus 60 / Focus 61 User Guide Working with Open Protocol 11.1 Getting Result via Atlas Open Protocol By the message “MID 0001 – Communication start”, a third application can start to communicate via Atlas Open Protocol with the Focus 61; the reply (MID 0002) contains the basic information about the controller. Working with Open Protocol Focus 60 / Focus 61 User Guide MID 0001 – Communication start First Step MID 0002 Second Step MID 0060 – Last tightening result data Third subscribe Step MID 0061 Fourth Step MID 0061 Fourth Step.
Focus 60 / Focus 61 User Guide Working with Open Protocol 11.2 Starting a Job via Atlas Open Protocol by means of VIN or Identifier By the message “MID 0001 – Communication start”, the Atlas Open Protocol starts to communicate with the Focus 61. Working with Open Protocol Focus 60 / Focus 61 User Guide In the third step the VIN (Vehicle ID Number) is subscribed by the Atlas Open Protocol. This means that every time when the controller receives a new VIN (e.g. Via barcode scanner), this VIN is transmitted to Atlas Open Protocol.
Working with ToolsNet WORKING WITH ToolsNet ToolsNet is an application that configures the Focus 60 / Focus 61, in order to allow to send data to the same ToolsNet. To enable this application, double-click the ToolsNet icon placed in the Device Files area (refer to the screen above: Connections section). Focus 60 / Focus 61 User Guide The CBP is a basic output protocol for tightening results. The default output port is 10001 on Ethernet interface A (1.2). Each dataset contains detailed information about the tightening according to the data output format listed in the table below: Ser. Keep the Focus 60 / Focus 61 clean.
After use, remove any traces of oil, grease and dust from the Focus 60 / Focus 61, especially from the user interfaces (for further details about the user interfaces, refer to the chapter “User Interfaces”). NOTE: Pay close attention during the execution of the next steps: the two Miniature Fuses could fall down on the floor.
This is due to the fact that it is not necessary to remove the Focus 60 / Focus 61 from its working position. By using a shaped tool (i.e.
Screwdriver), extract the Fuses Holder as shown in the picture on the right: 5. Fuses Holder into its housing as shown in the picture on the right: NOTE: Use ONLY the power cable provided with the Focus 60 / Focus 61 package. If you use any other power cable, the protection provided by the equipment may be impaired. Focus 60 / Focus 61 User Guide TROUBLESHOOTING GUIDE Here is a quick troubleshooting guide for the Focus 60 / Focus 61. If a problem occurs, before taking any action (replacing parts or contacting customer support), be sure to check that the Focus 60 / Focus 61 was used correctly. Index Focus 60 / Focus 61 User Guide 9839 02-01 Edition 1.1 www.atlascopco.com.